32 resultados para Digital image analysis

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Histopathological scoring of disease stage uses descriptive categories without measuring the amount of fibrosis. Collagen, the major component of fibrous tissue, can be quantified by computer-assisted digital image analysis (DIA) using histological sections. We determined relationships between DIA, Ishak stage, and hepatic venous pressure gradient (HVPG) reflecting severity of fibrosis. One hundred fifteen patients with hepatitis C virus (HCV) who had undergone transplantation had 250 consecutive transjugular liver biopsies combined with HVPG (median length, 22 mm; median total portal tracts, 12), evaluated using the Ishak system and stained with Sirus red for DIA. Liver collagen was expressed as collagen proportionate area (CPA). Median CPA was 6% (0.2-45), correlating with Ishak stage (stage 6 range, 13%-45%), and with HVPG (r = 0.62; P < 0.001). Median CPA was 4.1% when HVPG was less than 6 mm Hg and 13.8% when HVPG was 6 mm Hg or more (P < 0.0001) and 6% when HVPG was less than 10 mm Hg and 17.3% when HVPG was 10 mm Hg or higher (P < 0.0001). Only CPA, not Ishak stage/grade, was independently associated by logistic regression, with HVPG of 6 mm Hg or more [odds ratio, 1.206; 95% confidence interval (CI), 1.094-1.331; P < 0.001], or HVPG of 10 mm Hg or more (odds ratio, 1.105; 95% CI, 1.026-1.191; P = 0.009). CPA increased by 50% (3.6%) compared with 20% in HVPG (1 mm Hg) in 38 patients with repeated biopsies. Conclusion: CPA assessed by DIA correlated with Ishak stage scores and HVPG measured contemporaneously. CPA was a better histological correlate with HVPG than Ishak stage, had a greater numerical change when HVPG was low, and resulted in further quantitation of fibrosis in cirrhosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bubble characteristics such as shape, size, and trajectory control the hydrodynamics and therefore heat transfer in fluidized bed reactors. Thus understanding these characteristics is very important for the design and scaleup of fluidized beds. An earlier developed Eulerian-Eulerian two-fluid model for simulating dense gas–solid two-phase flow has been used to compare the experimental data in a pseudo-two-dimensional (2-D) bed. Bubbles are injected asymmetrically by locating the nozzle at proximity to the wall, thus presenting the effect wall has on asymmetrical injection as compared to symmetrical injection. In this work, a digital image analysis technique was developed to study the bubble behaviour in a two-dimensional bubbling bed. The high-speed photography reveals an asymmetric wake formation during detachment indicating an early onset of mixing process. The wall forces acts tangentially on thebubble and has a significant impact on the bubble shape, neck formation during detachment and its trajectory through the bed. Larger bubbles drifting away from the centre with longer paths are observed. This qualitative behaviour is well predicted by CFD modelling. Asymmetric injection can significantly influence the heat and mass transfer characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To describe the diagnostic performance of SolarScan (Polartechnics Ltd, Sydney, Australia), an automated instrument for the diagnosis of primary melanoma.

Design Images from a data set of 2430 lesions (382 were melanomas; median Breslow thickness, 0.36 mm) were divided into a training set and an independent test set at a ratio of approximately 2:1. A diagnostic algorithm (absolute diagnosis of melanoma vs benign lesion and estimated probability of melanoma) was developed and its performance described on the test set. High-quality clinical and dermoscopy images with a detailed patient history for 78 lesions (13 of which were melanomas) from the test set were given to various clinicians to compare their diagnostic accuracy with that of SolarScan.

Setting Seven specialist referral centers and 2 general practice skin cancer clinics from 3 continents. Comparison between clinician diagnosis and SolarScan diagnosis was by 3 dermoscopy experts, 4 dermatologists, 3 trainee dermatologists, and 3 general practitioners.

Patients Images of the melanocytic lesions were obtained from patients who required either excision or digital monitoring to exclude malignancy.

Main Outcome Measures Sensitivity, specificity, the area under the receiver operator characteristic curve, median probability for the diagnosis of melanoma, a direct comparison of SolarScan with diagnoses performed by humans, and interinstrument and intrainstrument reproducibility.

Results The melanocytic-only diagnostic model was highly reproducible in the test set and gave a sensitivity of 91% (95% confidence interval [CI], 86%-96%) and specificity of 68% (95% CI, 64%-72%) for melanoma. SolarScan had comparable or superior sensitivity and specificity (85% vs 65%) compared with those of experts (90% vs 59%), dermatologists (81% vs 60%), trainees (85% vs 36%; P =.06), and general practitioners (62% vs 63%). The intraclass correlation coefficient of intrainstrument repeatability was 0.86 (95% CI, 0.83-0.88), indicating an excellent repeatability. There was no significant interinstrument variation (P = .80).

Conclusions SolarScan is a robust diagnostic instrument for pigmented or partially pigmented melanocytic lesions of the skin. Preliminary data suggest that its performance is comparable or superior to that of a range of clinician groups. However, these findings should be confirmed in a formal clinical trial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is concerned with the construction of fracture envelopes of DP780 sheets using two methods: a hybrid experimental-numerical method; two-dimensional digital image correlation (2D-DIC). For the hybrid method, four types of ductile fracture tests were carried out covering a wide range of stress states on specimens: with a central hole; two symmetric circular notches; flat grooved; and diagonally double-notched. Based on the fracture strain and loading paths identified with finite element simulation, a fracture envelope was obtained by employing the three-parameter modified Mohr-Coulomb fracture model. In addition, the fracture surface strain was directly measured using 2D-DIC. Loading histories of each test were extracted from a surface element of a three dimensional finite element model. The comparison of fracture envelopes constructed by the two methods reveals that there is little difference. Thus, it can be concluded that 2D-DIC is applicable to fracture modelling of DP780 sheets despite the assumption of the plane stress condition even after necking

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nanoporous structure of membrane varies in 3-dimensional (3-D) space and has remarkable influences on the filtration or desalination achieved, fouling potentials and therefore, the quality of yielded water. Knowledge of the 3-D nanoporous structure is thus vital to understanding and predicting its performance. A novel method by incorporating transmission electronic microtomography, image processing and 3-D reconstruction is introduced to characterize membranes with nano structures. The reconstruction algorithm allows for the visualization of 3-D nanoporous structure in a non-destructive way from any directions. This novel technique Ieads to in-depth understanding and accurate prediction of filtration performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nanoporous structure of a membrane varies in a 3-dimensional (3-D) space and has remarkable influences on the filtration or desalination achieved, fouling potentials and therefore, the quality of yielded water. Knowledge of the 3-D nanoporous structure is thus vital to understanding and predicting its performance. A novel method by incorporating transmission electronic microtomography, image processing and 3-D reconstruction is introduced to characterize membranes with nano structures. The reconstruction algorithm allows for the visualization of 3-D nanoporous structure in a non-destructive way from any directions. This novel technique leads to in-depth understanding and accurate prediction of filtration performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis focuses on novel technologies for facial image analysis, which involves three topics: face recognition under uncontrolled conditions, automatic facial age estimation, and context-aware fusion of face and gait. They are either key issues bridging laboratorial research and real applications, or innovative problems that have barely been studied before.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current advancements in nanotechnology are dependent on the capabilities that can enable nano-scientists to extend their eyes and hands into the nano-world. For this purpose, a haptics (devices capable of recreating tactile or force sensations) based system for AFM (Atomic Force Microscope) is proposed. The system enables the nano-scientists to touch and feel the sample surfaces, viewed through AFM, in order to provide them with better understanding of the physical properties of the surface, such as roughness, stiffness and shape of molecular architecture. At this stage, the proposed work uses of ine images produced using AFM and perform image analysis to create virtual surfaces suitable for haptics force analysis. The research work is in the process of extension from of ine to online process where interaction will be done directly on the material surface for realistic analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The maximum a posteriori assignment for general structure Markov random fields is computationally intractable. In this paper, we exploit tree-based methods to efficiently address this problem. Our novel method, named Tree-based Iterated Local Search (T-ILS), takes advantage of the tractability of tree-structures embedded within MRFs to derive strong local search in an ILS framework. The method efficiently explores exponentially large neighborhoods using a limited memory without any requirement on the cost functions. We evaluate the T-ILS on a simulated Ising model and two real-world vision problems: stereo matching and image denoising. Experimental results demonstrate that our methods are competitive against state-of-the-art rivals with significant computational gain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research presents a novel rank based image watermarking method and improved moment based and histogram based image watermarking methods. A high-frequency component modification step is also proposed to compensate the side effect of commonly used Gaussian pre-filtering. The proposed methods outperform the latest image watermarking methods.